Grid metering · Head End System

See every sag, swell & harmonic across your grid.

RobustCore builds Class A grid power quality meters and a carrier-grade Head End System that turn millions of grid measurements into reliable, actionable data for utilities across India, the Middle East and neighbouring countries.

Class AIEC 61000-4-30
63rdHarmonic order
DLMS/COSEMOpen protocol
35+ yrsMetering expertise
Feeder 11kV-07 · RC-PQM Live
3-phase voltage waveform
R Y B
SAG -38%
V RMS6.35kV
THD-V3.8%
Pst0.62
Unbal.1.2%
Event captured · Voltage sag 0.62 pu, 140 ms · pushed to HES
Designed to standards IEC 61000-4-30 IEC 61000-4-7 IEC 61000-4-15 EN 50160 IEEE 519 DLMS/COSEM · IEC 62056 IS 15959 IS 16444
Products

From the measurement point to the control room.

Precision grid meters at the edge and a scalable Head End System at the core, designed together so data arrives complete, on time and trusted.

Grid Power Quality Meter

Class A meter for substations, feeders, boundary points and critical industrial loads.

  • Continuous capture of sags, swells, interruptions and transients
  • Harmonics and interharmonics up to the 63rd order
  • Flicker (Pst/Plt), unbalance and frequency deviation
  • Waveform recording with pre- and post-event cycles
  • Revenue-grade energy measurement in the same device
Accuracy classClass A · 0.2S energy
Sampling256 samples / cycle
CommunicationEthernet · RS-485 · 4G/LTE
ProtocolsDLMS/COSEM · Modbus · IEC 61850

Head End System (HES)

Carrier-grade data acquisition platform for meters at utility scale.

  • Scheduled and on-demand reads, events and load profiles
  • Remote configuration, connect/disconnect and firmware upgrades
  • Multi-vendor, multi-technology: RF mesh, cellular, PLC, fibre
  • Standard APIs to MDM, SCADA, ADMS and billing systems
  • Real-time dashboards, alarms and data-completeness reports
ArchitectureMicroservices · horizontally scalable
DeploymentOn-premise · private cloud · hybrid
IntegrationREST · MQTT · CIM (IEC 61968)
SecurityTLS · HLS keys · RBAC · audit trail
Platform

One data path, end to end.

Meters, communication, head end and enterprise systems working as a single, observable pipeline.

FIELD NETWORK CORE ENTERPRISE Grid PQ Meters Smart Meters DT / Feeder Meters 4G / LTE / NB-IoT RF Mesh PLC / Fibre HES Acquisition Validation Commands · FOTA Events · Alarms Security · Keys MDM SCADA / ADMS Billing / CIS PQ Analytics

Measure

Class A metering captures every disturbance at the source.

Connect

Any network, any meter vendor, with automatic retries and gap-fill.

Acquire

HES validates, stores and routes data at utility scale.

Act

Clean data feeds MDM, operations, billing and analytics.

Why RobustCore

Engineered for the realities of the grid.

Built by people who have spent decades designing metering products and systems for utilities.

Utility-scale ingestion

Scales horizontally from pilot projects to millions of endpoints without re-architecture.

High data completeness

Smart scheduling, automatic retries and gap detection keep daily read rates high.

Multi-vendor by design

Open DLMS/COSEM and IS 15959 support lets you mix meter makes on one platform.

Real-time event alerts

Sags, outages and tamper events pushed to operators within seconds, not the next read cycle.

Remote operations

Firmware upgrades, configuration changes and relay control across fleets, with full audit.

Compliance reporting

EN 50160 and IEEE 519 reports generated automatically for regulators and key accounts.

Power quality monitoring

Every parameter that matters.

Measured to IEC 61000-4-30 Class A methods, so results are comparable across devices and sites.

DIP / SWELL

Voltage events

Sags, swells and interruptions with duration and depth.

THD · Hn

Harmonics

Voltage and current harmonics and interharmonics.

Pst · Plt

Flicker

Short- and long-term flicker severity per IEC 61000-4-15.

u2 · u0

Unbalance

Negative and zero-sequence voltage unbalance.

Δf

Frequency

10-second frequency and deviation statistics.

TRANSIENT

Transients

Fast transient capture with waveform records.

PF · DPF

Power factor

True and displacement power factor per phase.

kWh · kVArh

Energy

Import/export active, reactive and apparent energy.

Grid segments

Built for every point on the grid.

From transmission substations to the industrial meter room.

Transmission

Substation PQ and grid-code compliance.

Distribution utilities

Feeder, DT and boundary metering under one HES.

Renewables

Solar and wind plant grid-connection monitoring.

Industrial

Protect sensitive processes and avoid penalties.

Data centres

Continuous PQ for mission-critical uptime.

Serving utilities in India Middle East & GCC Neighbouring countries
Design services

Products, plus the expertise behind them.

Beyond our own products, we help utilities and manufacturers solve the harder problems in metering and energy systems.

Product & system design

End-to-end design of meters and metering systems, from architecture and specifications to market-ready products.

Technology strategy

Roadmaps, build-versus-buy decisions and architecture reviews for AMI, HES and grid-edge platforms.

Technical advisory

Independent advice for utilities and organisations navigating the changing energy landscape.

About us

Led by 35+ years of metering experience.

Pratik Kumar Das

Pratik Kumar Das

Founder & Proprietor

35+Years in metering
CTOFormer, Energy BU
View LinkedIn profile

Pratik founded RobustCore Design Services after more than 35 years in the metering and energy domain, including serving as Chief Technology Officer of the Energy Business Unit at Secure Meters Limited.

Over that time he led end-to-end product and system development, delivering innovative and scalable solutions across utilities and energy ecosystems. He built and led high-performance engineering teams, drove technology strategy, and translated business needs into products that reached the market.

He now works independently with organisations as a technical consultant and adviser, with a particular interest in advisory roles, product strategy and the harder problems of the changing energy landscape.

Metering & AMI Product strategy System architecture Engineering leadership Technical advisory
Security & reliability

Critical infrastructure deserves critical-grade security.

Security is designed in from meter to API, aligned with utility cyber-security requirements and audit expectations.

01

End-to-end encryption

DLMS high-level security (HLS) on meters and TLS on every connection.

02

Key management

Per-device keys with secure rotation and HSM support.

03

Role-based access & audit

Granular permissions with every command and change logged.

04

High availability

Active-active clustering and disaster recovery options.

Get in touch

Ready to see your grid clearly?

Talk to us about a pilot, a technical deep-dive, a live demo of the Head End System, or a design and advisory engagement.